INSTALLATION INSTRUCTIONS
PROFESSIONAL RANGE MODELS
36” ALL GAS, CONVECTION WITH SEALED BURNERS**
36” NATURAL GAS MODELS
*TN331-7BW
*TN331-7W
**THESE MODELS ARE NOT FIELD CONVERITBLE FOR LP/PROPANE GAS. THEY MUST BE
ORDERED FROM THE FACTORY SET FOR NATURAL OR LP/PROPANE GAS.**
36” LP/PROPANE GAS MODELS
*PN331-7BW
*PN331-7W
**THESE MODELS ARE NOT FIELD CONVERTIBLE FOR NATURAL GAS. THEY MUST BE
ORDERED FROM THE FACTORY SET FOR NATURAL OR LP/PROPANE GAS.**
IF YOU HAVE QUESTIONS, CALL 800-251-7224, 8 AM TO 5 PM EASTERN TIME, OR VISIT OUR
WEBSITE, WWW.FIVESTARRANGE.COM.
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS PROFESSIONAL RANGE MODELS 36” ALL GAS, CONVECTION WITH SEALED BURNERS** 36” NATURAL GAS MODELS *TN331-7BW *TN331-7W **

Page 3

STEP 12 OVEN OPERATION GAS OVEN • Turn oven thermostat knob counter clockwise to 350°. • The oven burner should light within 60 seconds. GRIDDLE

Page 4 - REMOVE PACKAGING

STEP 14 CHECKLIST FOR SEALED BURNER INSTALLATION  MAKE SURE ALL CONTROLS ARE IN THE “OFF” POSITION.  Gas supply is “on”  Electric power is

Page 5 - 120 volts, 60 Hz, 15 amps

Installation Instructions BEFORE YOU BEGIN CAUTION: Read these instructions completely and carefully. THESE RANGES S

Page 6

INSTALLATION INSTRUCTIONS Please read these instructions before attempting to install this range Inspection and Unpacking Check the range carton

Page 7

STEP 1 REMOVE PACKAGING Before moving the range indoors:  Remove outer carton and packing material from the shipping base. The range is now r

Page 8 - DIAGRAM FOR STEP 7

STEP 5 ELECTRIC CONNECTION This range must be supplied with 120 volt, 60 Hz. and connected to an individual, properly grounded branch circuit protec

Page 10

STEP 7 INSTALLING THE BACKGUARD – SEALED BURNER MODELS NOTE: PLEASE READ ALL INSTRUCTIONS BEFORE STARTING INSTALLATION. 7-1 Remove the burner grates

Page 11 - STEP 13

DIAGRAM FOR STEP 7 STEP 8 LEVEL THE RANGE 1. Remove shipping tape from the leveling legs. 2. Carefully slide the range into position. Be ca